Configuração do ClienteDispositivos e EndpointsDispositivosIntegração de DispositivosHTTPAPI HTTPArmazenamento de Dados de Sensores
Appliances and Other On/Off Devices
Reporting Endpoint Status
The HTTP integration of appliances and other on/off devices (valves, lamps, motors, etc.) uses the following structure:
POST /services/gear/DeviceIntegrationService.svc/UpdateApplianceStatus HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json
{
"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
"endpointID": 1,
"isOn": true,
"timestamp": "2021-02-23T14:55:03"
}Parameters
| Name | Description | Data Type |
|---|---|---|
| accessToken | Access token with permissions to update endpoint information. See this page for more information. | text |
| endpointID | Unique endpoint identifier or combination of device address and endpoint address in format [deviceAddress]:endpointAddress (e.g.: [device-1234]:1). These values can be found on the endpoint management page. | numeric |
| isOn | Whether the appliance is on (true) or off (false). | bool |
| timestamp | Optional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time. | text |
Reporting Status in "raw" Format
The endpoint state can be reported as a raw value using the expression converter. This option is convenient when the device is unable to perform conversions and emits values that need to be transformed before being injected into the platform.
Below is an example of a raw format request:
POST /services/gear/DeviceIntegrationService.svc/UpdateApplianceStatusRaw HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json
{
"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
"endpointID": 1,
"rawData": "true",
"timestamp": "2021-02-23T14:55:03"
}Parameters
| Name | Description | Data Type |
|---|---|---|
| accessToken | Access token with permissions to update endpoint information. See this page for more information. | text |
| endpointID | Unique endpoint identifier, which can be found on the endpoint management page. | numeric |
| rawData | Value reported by the sensor, as text. An expression must be specified in the expression converter. The expression must return a boolean indicating whether the appliance is on (true) or off (false). | text |
| timestamp | Optional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time. | text |
Última atualização em
Generic Flow Sensors
How to send flow readings from a generic sensor, in its variable type's unit, to Gear Studio through the HTTP API: request structure and parameters.
Dimmers
How to send the level of a dimmer or speed controller to Gear Studio through the HTTP API: request structure, parameters and an example.