Ir para o conteúdo principal
CloudStudio

Battery and RSSI Status

Report the RSSI Status and/or Battery Level of a Device

This method does not store a history of the status; it only takes the last reported value and displays it on the platform. That is, if 3 batteries were reported in the first request and only one is reported in the second request, then it is assumed that the device now has only one battery. The same applies to RSSI. If empty arrays are sent, it will be assumed that there is no battery level or RSSI record and previously reported data will be cleared.

The HTTP integration for RSSI status and battery level uses the following structure:

POST /services/gear/DeviceIntegrationService.svc/UpdateDeviceStatus HTTP/1.1
Host: gear-dev.cloud.studio
Content-Type: application/json

{
	"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
	"deviceID": 1,
	"battery": [
		{
			"type": 2,
			"percentage": 30,
			"voltage": 3.5
		},
		{
			"type": 3,
			"percentage": 100,
			"voltage": 5
		}
	],
	"rssi": [
		{
			"type": 2,
			"quality": 100,
			"strength": -40
		}
	]
}

Parameters

NameDescriptionData Type
accessTokenAccess token with permissions to update endpoint information. See this page for more information.text
deviceIDUnique device identifier or device address in format [deviceAddress] (e.g.: [device-1234]). These values can be found on the device management page.number
batteryList of statuses for the device's different batteries. One or more can be sent. Property descriptions for this parameter can be found below.array
rssiList of statuses for the device's different wireless connections. One or more can be sent. Property descriptions for this parameter can be found below.array

"battery" Array Parameter

In each element of this array, at least "percentage" or "voltage" must be reported. Type is mandatory.

NameDescriptionData Type
typeType of battery being reported. Allowed types are: 0: Unknown. If this value is sent, it will automatically be changed to 1. 1: Default. 2: Primary. 3: Secondary. 4: Backup. Types cannot be repeated in the same array.number
percentageNumeric value of the remaining battery percentage.number
voltageNumeric value of the current battery voltage.number

"rssi" Array Parameter

In each element of this array, at least "quality" or "strength" must be reported. Type is mandatory.

NameDescriptionData Type
typeRepresents a type of wireless technology where RSSI can be measured. Allowed values are: 0: Unknown. If this value is sent, it will automatically be changed to 1. 1: Default. 2: WiFi. 3: LoRaWAN. 4: Cellular (2G/3G/4G/5G/Cat-M/NB-IoT/etc). 5: ZigBee. 6: Custom RF. Types cannot be repeated in the same array.number
qualityNumeric value representing signal quality. From 0 to 100. If this value is not provided but the "strength" parameter is, this parameter's value will be auto-calculated.number
strengthNumeric value representing signal strength in dBm (negative). If the provided value is positive, its sign will be changed. If this value is not provided but the "quality" parameter is, this parameter's value will be auto-calculated.number