Zum Hauptinhalt springen
CloudStudio

Frequenzmesser

Frequenzmeldung in Hertz

The integration de frecuencímetros por MQTT uses the following structure:

{
	"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
	"endpointID": 1,
	"frequency": 45,
	"timestamp": "2021-02-23T14:55:03",
	"mqttMethod": "UpdateFrequencySensorStatus",
	"mqttRID": "tkrs34"
}

Parameter

NameDescriptionData Type
accessTokenAccess token with permissions to update endpoint information. See this page for more information.text
endpointIDUnique endpoint identifier or combination of device address and endpoint address in format [deviceAddress]:endpointAddress (e.g.: [device-1234]:1). These values can be found on the endpoint management page.text
frequencyFrecuencia expresada en Hertz.numeric
timestampOptional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time.text
mqttMethodMétodo correspondiente del servicio, en este caso UpdateFrequencySensorStatusstring
mqttRIDIdentificador opcional para la petición, en caso de que se desee obtener una respuesta de confirmación.string

Reporte de frecuencia en formato "raw"

La frecuencia puede ser reportada como un Rohwert, mit dem Ausdruckskonverter. Diese Option ist sinnvoll, wenn das Gerät keine Konvertierungen vornehmen kann und Werte ausgibt, die transformiert werden müssen, bevor sie in die Plattform eingespeist werden.

Nachfolgend ein Beispiel einer Anfrage im raw-Format:

{
	"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
	"endpointID": 1,
	"rawData": "45",
	"timestamp": "2021-02-23T14:55:03",
	"mqttMethod": "UpdateFrequencySensorStatusRaw",
	"mqttRID": "tkrs34"
}

Parameter

NameDescriptionData Type
accessTokenAccess token with permissions to update endpoint information. See this page for more information.text
endpointIDUnique endpoint identifier, which can be found on the endpoint management page.numeric
rawDataValor reportado por el sensor, como texto. Debe indicarse una expresión en el conversor de expresiones. La expresión debe devolver un valor numérico indicando la frecuencia, expresada en Hertz.text
timestampOptional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time.text
mqttMethodMétodo correspondiente del servicio, en este caso UpdateFrequencySensorStatusRawstring
mqttRIDIdentificador opcional para la petición, en caso de que se desee obtener una respuesta de confirmación.string

Zuletzt aktualisiert am