Zum Hauptinhalt springen
CloudStudio

Blindleistungssensoren

Blindleistungsmeldung in VAR

Die Sensorintegration für Blindleistung über HTTP verwendet folgende Struktur:

POST /services/gear/DeviceIntegrationService.svc/UpdateReactivePowerSensorStatus HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json

{
	"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
	"endpointID": 1,
	"reactivePowerVAR": 2850.5,
	"timestamp": "2021-02-23T14:55:03"
}

Parameter

NameDescriptionData Type
accessTokenAccess token with permissions to update endpoint information. See this page for more information.text
endpointIDUnique endpoint identifier or combination of device address and endpoint address in format [deviceAddress]:endpointAddress (e.g.: [device-1234]:1). These values can be found on the endpoint management page.numeric
reactivePowerVARReactive power, expressed in VAR.numeric
timestampOptional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time.text

Reporting Reactive Power in "raw" Format

Reactive power can be reported as a Rohwert mit dem Ausdruckskonverter. Diese Option ist sinnvoll, wenn das Gerät keine Konvertierungen vornehmen kann und Werte ausgibt, die transformiert werden müssen, bevor sie in die Plattform eingespeist werden.

Nachfolgend ein Beispiel einer Anfrage im raw-Format:

POST /services/gear/DeviceIntegrationService.svc/UpdateReactivePowerSensorStatusRaw HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json

{
	"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
	"endpointID": 1,
	"rawData": "2850.5",
	"timestamp": "2021-02-23T14:55:03"
}

Parameter

NameDescriptionData Type
accessTokenAccess token with permissions to update endpoint information. See this page for more information.text
endpointIDUnique endpoint identifier, which can be found on the endpoint management page.numeric
rawDataValue reported by the sensor, as text. An expression must be specified in the expression converter. La expresión debe devolver un valor numérico indicando la potencia reactiva, expresada en VAR.text
timestampOptional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time.text