Gewichtssensoren

Gewicht in Gramm melden

Die HTTP-Integration von Gewichtssensoren verwendet die folgende Struktur:

POST /services/gear/DeviceIntegrationService.svc/UpdateWeightSensorStatus HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json

{
	"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
	"endpointID": 1,
	"weightGrams": 4500,
	"timestamp": "2021-02-23T14:55:03"
}

Parameter

NameDescriptionData Type
accessTokenAccess token with permissions to update endpoint information. See this page for more information.text
endpointIDUnique endpoint identifier or combination of device address and endpoint address in format [deviceAddress]:endpointAddress (e.g.: [device-1234]:1). These values can be found on the endpoint management page.text
weightGramsWeight, expressed in grams.numeric
timestampOptional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time.text

Gewicht im "raw"-Format melden

Gewicht kann als Rohwert unter Verwendung des Ausdruckskonverters gemeldet werden. Diese Option ist praktisch, wenn das Gerät keine Konvertierungen durchführen kann und Werte ausgibt, die transformiert werden müssen, bevor sie in die Plattform eingefügt werden.

Nachfolgend ein Beispiel für eine Anfrage im Rohformat:

POST /services/gear/DeviceIntegrationService.svc/UpdateWeightSensorStatusRaw HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json

{
	"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
	"endpointID": 1,
	"rawData": "4500",
	"timestamp": "2021-02-23T14:55:03"
}

Parameter

NameDescriptionData Type
accessTokenAccess token with permissions to update endpoint information. See this page for more information.text
endpointIDUnique endpoint identifier, which can be found on the endpoint management page.numeric
rawDataValue reported by the sensor, as text. An expression must be specified in the expression converter. The expression must return a numeric value indicating weight, expressed in grams.text
timestampOptional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time.text