Zum Hauptinhalt springen
CloudStudio

Cos-Phi-Sensoren

Cos-Phi-Meldung

Die Sensorintegration für Cosinus Phi über HTTP verwendet folgende Struktur:

POST /services/gear/DeviceIntegrationService.svc/UpdateCosPhiSensorStatus HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json

{
	"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
	"endpointID": 1,
	"cosPhi": 0.96,
	"timestamp": "2021-02-23T14:55:03"
}

Parameter

NameDescriptionData Type
accessTokenAccess token with permissions to update endpoint information. See this page for more information.text
endpointIDUnique endpoint identifier or combination of device address and endpoint address in format [deviceAddress]:endpointAddress (e.g.: [device-1234]:1). These values can be found on the endpoint management page.numeric
cosPhiCoseno fi, en el rango de -1 a 1.numeric
timestampOptional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time.text

Cos-Phi-Meldung im „raw"-Format

Cos phi can be reported as a Rohwert mit dem Ausdruckskonverter. Diese Option ist sinnvoll, wenn das Gerät keine Konvertierungen vornehmen kann und Werte ausgibt, die transformiert werden müssen, bevor sie in die Plattform eingespeist werden.

Nachfolgend ein Beispiel einer Anfrage im raw-Format:

POST /services/gear/DeviceIntegrationService.svc/UpdateCosPhiSensorStatusRaw HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json

{
	"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
	"endpointID": 1,
	"rawData": "0.96",
	"timestamp": "2021-02-23T14:55:03"
}

Parameter

NameDescriptionData Type
accessTokenAccess token with permissions to update endpoint information. See this page for more information.text
endpointIDUnique endpoint identifier, which can be found on the endpoint management page.numeric
rawDataValue reported by the sensor, as text. An expression must be specified in the expression converter. La expresión debe devolver un valor numérico indicando el coseno fi, en el rango de -1 a 1.text
timestampOptional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time.text

Zuletzt aktualisiert am

Auf dieser Seite