Zum Hauptinhalt springen
CloudStudio

HVAC / Thermostate

Meldung des HVAC-Gerätestatus

Die HTTP-Integration von HVAC-Geräten verwendet die folgende Struktur:

POST /services/gear/DeviceIntegrationService.svc/UpdateHVACStatus HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json

{
	"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
	"endpointID": 1,
	"mode": 4,
	"fanMode": 1,
	"setpoint": 21,
	"ambientTemperature": 21.5,
	"timestamp": "2021-02-23T14:55:03"
}

Parameter

NameDescriptionData Type
accessTokenAccess token with permissions to update endpoint information. See this page for more information.text
endpointIDUnique endpoint identifier or combination of device address and endpoint address in format [deviceAddress]:endpointAddress (e.g.: [device-1234]:1). These values can be found on the endpoint management page.numeric
modeModo actual del dispositivo:1: el dispositivo está apagado.2: el dispositivo está encendido en modo automático.3: el dispositivo está encendido en modo calor.4: el dispositivo está encendido en modo frío.5: el dispositivo está encendido en modo deshumidificación.6: el dispositivo está encendido en modo ventilador.numeric
fanModeModo actual del ventilador:1: el ventilador está en modo automático.2: el ventilador está en velocidad baja.3: el ventilador está en velocidad media.4: el ventilador está en velocidad alta.numeric
setpointIndica el valor de temperatura deseado, en grados Celsius.numeric
ambientTemperatureIndica el valor de la temperatura ambiente, en grados Celsius.numeric
timestampOptional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time.text

Zuletzt aktualisiert am

Auf dieser Seite