Decodificador y payload LoRaWAN de Ezurio Sentrius RS26x
El Ezurio Sentrius RS26x es un sensor LoRaWAN de temperatura que informa temperatura. Tiene protección IP67, funciona con batería reemplazable (CR123A) y opera entre -25 y 85 °C.
Formato del payload
Un uplink del equipo tal como llega al servidor de red, y lo que devuelve el decodificador oficial. Los ejemplos salen de los casos de prueba del propio decodificador.
Ejemplo 1 · fPort 1
Payload (hex)
00 C0 00 14 80 01 68 7E 48 B6 05 19 01 68 7E 48 D4 04 00 01 68 7E 48 F2 02 E6 01 68 7E 49 10 01 CC 01 68 7E 49 2E 00 B3 01 68 7E 49 4C FF 9A 01 68 7E 49 6A FE 80 01 68 7E 49 88 FD 67 01 68 7E 49 A6 FC 4D 01 68 7E 49 C4 FB 34Decodificado (JSON)
{
"Battery Status": "Good",
"Device Status": {
"Backlog Wraparound": "No",
"Backlogs Available": "No",
"Bandwidth Limitation": "No",
"Sensor Fault": "No",
"Unsupported API Version": "No"
},
"Temperature": 20.5,
"Temperature Backlog 1": {
"Temperature": 5.1,
"Timestamp": "Mon, 21 Jul 2025 14:03:34 GMT"
},
"Temperature Backlog 2": {
"Temperature": 4,
"Timestamp": "Mon, 21 Jul 2025 14:04:04 GMT"
},
"Temperature Backlog 3": {
"Temperature": 2.9,
"Timestamp": "Mon, 21 Jul 2025 14:04:34 GMT"
},
"Temperature Backlog 4": {
"Temperature": 1.8,
"Timestamp": "Mon, 21 Jul 2025 14:05:04 GMT"
},
"Temperature Backlog 5": {
"Temperature": 0.7,
"Timestamp": "Mon, 21 Jul 2025 14:05:34 GMT"
},
"Temperature Backlog 6": {
"Temperature": -0.4,
"Timestamp": "Mon, 21 Jul 2025 14:06:04 GMT"
},
"Temperature Backlog 7": {
"Temperature": -1.5,
"Timestamp": "Mon, 21 Jul 2025 14:06:34 GMT"
},
"Temperature Backlog 8": {
"Temperature": -2.6,
"Timestamp": "Mon, 21 Jul 2025 14:07:04 GMT"
},
"Temperature Backlog 9": {
"Temperature": -3.7,
"Timestamp": "Mon, 21 Jul 2025 14:07:34 GMT"
},
"Temperature Backlog 10": {
"Temperature": -4.8,
"Timestamp": "Mon, 21 Jul 2025 14:08:04 GMT"
}
}| Campo | Valor |
|---|---|
| Battery Status | Good |
| Device Status.Backlog Wraparound | No |
| Device Status.Backlogs Available | No |
| Device Status.Bandwidth Limitation | No |
| Device Status.Sensor Fault | No |
| Device Status.Unsupported API Version | No |
| Temperature | 20.5 |
| Temperature Backlog 1.Temperature | 5.1 |
| Temperature Backlog 1.Timestamp | Mon, 21 Jul 2025 14:03:34 GMT |
| Temperature Backlog 2.Temperature | 4 |
| Temperature Backlog 2.Timestamp | Mon, 21 Jul 2025 14:04:04 GMT |
| Temperature Backlog 3.Temperature | 2.9 |
| Temperature Backlog 3.Timestamp | Mon, 21 Jul 2025 14:04:34 GMT |
| Temperature Backlog 4.Temperature | 1.8 |
| Temperature Backlog 4.Timestamp | Mon, 21 Jul 2025 14:05:04 GMT |
| Temperature Backlog 5.Temperature | 0.7 |
| Temperature Backlog 5.Timestamp | Mon, 21 Jul 2025 14:05:34 GMT |
| Temperature Backlog 6.Temperature | -0.4 |
| Temperature Backlog 6.Timestamp | Mon, 21 Jul 2025 14:06:04 GMT |
| Temperature Backlog 7.Temperature | -1.5 |
| Temperature Backlog 7.Timestamp | Mon, 21 Jul 2025 14:06:34 GMT |
| Temperature Backlog 8.Temperature | -2.6 |
| Temperature Backlog 8.Timestamp | Mon, 21 Jul 2025 14:07:04 GMT |
| Temperature Backlog 9.Temperature | -3.7 |
| Temperature Backlog 9.Timestamp | Mon, 21 Jul 2025 14:07:34 GMT |
| Temperature Backlog 10.Temperature | -4.8 |
| Temperature Backlog 10.Timestamp | Mon, 21 Jul 2025 14:08:04 GMT |
Ejemplo 2 · fPort 1
Payload (hex)
00 C0 01 68 7E 48 B6 05 19 01 68 7E 48 D4 04 00 01 68 7E 48 F2 02 E6 01 68 7E 49 10 01 CC 01 68 7E 49 2E 00 B3 01 68 7E 49 4C FF 9A 01 68 7E 49 6A FE 80 01 68 7E 49 88 FD 67 01 68 7E 49 A6 FC 4D 01 68 7E 49 C4 FB 34Decodificado (JSON)
{
"Battery Status": "Good",
"Device Status": {
"Backlog Wraparound": "No",
"Backlogs Available": "No",
"Bandwidth Limitation": "No",
"Sensor Fault": "No",
"Unsupported API Version": "No"
},
"Temperature Backlog 1": {
"Temperature": 5.1,
"Timestamp": "Mon, 21 Jul 2025 14:03:34 GMT"
},
"Temperature Backlog 2": {
"Temperature": 4,
"Timestamp": "Mon, 21 Jul 2025 14:04:04 GMT"
},
"Temperature Backlog 3": {
"Temperature": 2.9,
"Timestamp": "Mon, 21 Jul 2025 14:04:34 GMT"
},
"Temperature Backlog 4": {
"Temperature": 1.8,
"Timestamp": "Mon, 21 Jul 2025 14:05:04 GMT"
},
"Temperature Backlog 5": {
"Temperature": 0.7,
"Timestamp": "Mon, 21 Jul 2025 14:05:34 GMT"
},
"Temperature Backlog 6": {
"Temperature": -0.4,
"Timestamp": "Mon, 21 Jul 2025 14:06:04 GMT"
},
"Temperature Backlog 7": {
"Temperature": -1.5,
"Timestamp": "Mon, 21 Jul 2025 14:06:34 GMT"
},
"Temperature Backlog 8": {
"Temperature": -2.6,
"Timestamp": "Mon, 21 Jul 2025 14:07:04 GMT"
},
"Temperature Backlog 9": {
"Temperature": -3.7,
"Timestamp": "Mon, 21 Jul 2025 14:07:34 GMT"
},
"Temperature Backlog 10": {
"Temperature": -4.8,
"Timestamp": "Mon, 21 Jul 2025 14:08:04 GMT"
}
}| Campo | Valor |
|---|---|
| Battery Status | Good |
| Device Status.Backlog Wraparound | No |
| Device Status.Backlogs Available | No |
| Device Status.Bandwidth Limitation | No |
| Device Status.Sensor Fault | No |
| Device Status.Unsupported API Version | No |
| Temperature Backlog 1.Temperature | 5.1 |
| Temperature Backlog 1.Timestamp | Mon, 21 Jul 2025 14:03:34 GMT |
| Temperature Backlog 2.Temperature | 4 |
| Temperature Backlog 2.Timestamp | Mon, 21 Jul 2025 14:04:04 GMT |
| Temperature Backlog 3.Temperature | 2.9 |
| Temperature Backlog 3.Timestamp | Mon, 21 Jul 2025 14:04:34 GMT |
| Temperature Backlog 4.Temperature | 1.8 |
| Temperature Backlog 4.Timestamp | Mon, 21 Jul 2025 14:05:04 GMT |
| Temperature Backlog 5.Temperature | 0.7 |
| Temperature Backlog 5.Timestamp | Mon, 21 Jul 2025 14:05:34 GMT |
| Temperature Backlog 6.Temperature | -0.4 |
| Temperature Backlog 6.Timestamp | Mon, 21 Jul 2025 14:06:04 GMT |
| Temperature Backlog 7.Temperature | -1.5 |
| Temperature Backlog 7.Timestamp | Mon, 21 Jul 2025 14:06:34 GMT |
| Temperature Backlog 8.Temperature | -2.6 |
| Temperature Backlog 8.Timestamp | Mon, 21 Jul 2025 14:07:04 GMT |
| Temperature Backlog 9.Temperature | -3.7 |
| Temperature Backlog 9.Timestamp | Mon, 21 Jul 2025 14:07:34 GMT |
| Temperature Backlog 10.Temperature | -4.8 |
| Temperature Backlog 10.Timestamp | Mon, 21 Jul 2025 14:08:04 GMT |
Especificaciones
- Fabricante
- Ezurio
- Modelo
- Sentrius RS26x
- Tipo
- Sensor de temperatura
- Mide
- temperatura
- Protección
- IP67
- Batería
- CR123A (reemplazable)
- Temperatura de trabajo
- -25 … 85 °C
- Regiones LoRaWAN
- AS923, AU915-928, EU863-870, US902-928
Conéctalo a Cloud Studio IoT
- 1
Registra el equipo en tu servidor de red
Añádelo a The Things Stack, ChirpStack, Actility ThingPark o LORIOT con su DevEUI, JoinEUI y AppKey y el plan de frecuencias de tu región.
- 2
Aplica el decodificador
En The Things Stack, elige el modelo del repositorio de dispositivos y su decodificador se aplica solo. En ChirpStack v4, pega el decodificador oficial como codec JavaScript del perfil de dispositivo.
- 3
Conecta el servidor de red a Cloud Studio IoT
Configura la integración una vez por servidor de red; a partir de ahí, cada equipo registrado llega a Cloud Studio IoT con sus valores decodificados.
- 4
Crea dashboards y alarmas
Los campos decodificados se convierten en variables del dispositivo para dashboards, alarmas por email o SMS e informes programados.
Mira tu Ezurio Sentrius RS26x en un dashboard
Empieza una prueba gratuita, da de alta el equipo con su DevEUI y ten dashboards y alarmas desde su siguiente uplink.
Preguntas frecuentes
Datos del equipo y ejemplos del decodificador: repositorio de dispositivos de The Things Network (Apache-2.0) · commit 7693223, importado el 2026-10-05.