Humidity Sensors
Reporting Humidity as Percentage
The integration de sensores de humedad por MQTT uses the following structure:
{
"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
"endpointID": 1,
"humidityPercentage": 20,
"timestamp": "2021-02-23T14:55:03",
"mqttMethod": "UpdateHumiditySensorStatus",
"mqttRID": "RXmp123"
}Parameters
| Name | Description | Data Type |
|---|---|---|
| accessToken | Access token with permissions to update endpoint information. See this page for more information. | text |
| endpointID | Unique endpoint identifier or combination of device address and endpoint address in format [deviceAddress]:endpointAddress (e.g.: [device-1234]:1). These values can be found on the endpoint management page. | text |
| humidityPercentage | Humidity percentage, from 0 to 100. | text |
| timestamp | Optional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time. | text |
| mqttMethod | Método correspondiente del servicio, en este caso UpdateHumiditySensorStatus | string |
| mqttRID | Identificador opcional para la petición, en caso de que se desee obtener una respuesta de confirmación. | string |
Reporte de humedad en formato "raw"
La humedad puede ser reportada como un valor crudo (raw), utilizando el conversor de expresiones. Esta opción es conveniente cuando el dispositivo no es capaz de realizar conversiones, y emite valores que necesitan ser transformados antes de inyectarse en la plataforma.
A continuación, se muestra un ejemplo de una petición en formato raw:
{
"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
"endpointID": 1,
"rawData": "25",
"timestamp": "2021-02-23T14:55:03",
"mqttMethod": "UpdateHumiditySensorStatusRaw",
"mqttRID": "RXmp123"
}Parameters
| Name | Description | Data Type |
|---|---|---|
| accessToken | Access token with permissions to update endpoint information. See this page for more information. | text |
| endpointID | Unique endpoint identifier, which can be found on the endpoint management page. | numeric |
| rawData | Valor reportado por el sensor, como texto. Debe indicarse una expresión en el conversor de expresiones. La expresión debe devolver un valor numérico entre 0 y 100. | text |
| timestamp | Optional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time. | text |
| mqttMethod | Método correspondiente del servicio, en este caso UpdateHumiditySensorStatusRaw | string |
| mqttRID | Identificador opcional para la petición, en caso de que se desee obtener una respuesta de confirmación. | string |