Voltage Sensors
Reporting Voltage in Volts
The HTTP integration of voltage sensors uses the following structure:
POST /services/gear/DeviceIntegrationService.svc/UpdateVoltageSensorStatus HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json
{
"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
"endpointID": 1,
"voltageVolts": 45,
"timestamp": "2021-02-23T14:55:03"
}Parameters
| Name | Description | Data Type |
|---|---|---|
| accessToken | Access token with permissions to update endpoint information. See this page for more information. | text |
| endpointID | Unique endpoint identifier or combination of device address and endpoint address in format [deviceAddress]:endpointAddress (e.g.: [device-1234]:1). These values can be found on the endpoint management page. | numeric |
| voltageVolts | Voltage expressed in volts. | numeric |
| timestamp | Optional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time. | text |
Reporting Voltage in "raw" Format
Voltage can be reported as a raw value using the expression converter. This option is convenient when the device is unable to perform conversions and emits values that need to be transformed before being injected into the platform.
Below is an example of a raw format request:
POST /services/gear/DeviceIntegrationService.svc/UpdateVoltageSensorStatusRaw HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json
{
"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
"endpointID": 1,
"rawData": "45",
"timestamp": "2021-02-23T14:55:03"
}Parameters
| Name | Description | Data Type |
|---|---|---|
| accessToken | Access token with permissions to update endpoint information. See this page for more information. | text |
| endpointID | Unique endpoint identifier, which can be found on the endpoint management page. | numeric |
| rawData | Value reported by the sensor, as text. An expression must be specified in the expression converter. The expression must return a numeric value indicating voltage, expressed in volts. | text |
| timestamp | Optional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time. | text |